Stray Current Monitoring System

Secheron Stray Current Monitoring System (SCMS) is a straightforward and efficient method of stray current monitoring avoiding manual repetitive measurement and any interference with the stray current collecting system. The system measures continuously the rail-to-earth potential under operational conditions, complete with central analysis, visualization, signaling and archiving capacities.
Real time measurements
Alarm and localization of the detected insulation fau
Data acquisition and transmission through the communication network
Permanent automatic analysis of recorded values and manual analysis possible
Set up of network lines and stations, up to 100 control points
Determination on data reference
Integration of specific algorithm depending on the type of network
Export and backup of measured and recorded values
Communication with SCADA system
No interference with Stray Current Collection System
Measure
Maximum number of measuring points100 for one system
Frequency of acquisition1 sec
Communication
Communication protocolsIEC 61850, IEC 60870-5-104 (-5-101), Modbus TCP
Visualization and Archiving
Total memory size1 TB
Available LanguagesMulti-languages (can be adjusted)
Analysis
Number of acquisitions for the reference profile10 most relevant measurements
Number of acquisitions (global)All points for 16 weeks Mean Values saved for 10 years

Related Products