Stray Current Monitoring System

Secheron Stray Current Monitoring System (SCMS) is a
straightforward and efficient method of stray current
monitoring avoiding manual repetitive measurement and any
interference with the stray current collecting system. The
system measures continuously the rail-to-earth potential under
operational conditions, complete with central analysis,
visualization, signaling and archiving capacities.
Real time measurements
Alarm and localization of the detected insulation fau
Data acquisition and transmission through the communication network
Permanent automatic analysis of recorded values and manual analysis possible
Set up of network lines and stations, up to 100 control points
Determination on data reference
Integration of specific algorithm depending on the type of network
Export and backup of measured and recorded values
Communication with SCADA system
No interference with Stray Current Collection System
| Measure | |
| Maximum number of measuring points | 100 for one system |
| Frequency of acquisition | 1 sec |
| Communication | |
| Communication protocols | IEC 61850, IEC 60870-5-104 (-5-101), Modbus TCP |
| Visualization and Archiving | |
| Total memory size | 1 TB |
| Available Languages | Multi-languages (can be adjusted) |
| Analysis | |
| Number of acquisitions for the reference profile | 10 most relevant measurements |
| Number of acquisitions (global) | All points for 16 weeks Mean Values saved for 10 years |